Range:
models available

Operating range:
Cooling Capacity: 8,5 to 18 kW

Use :

Air/water single unit cooling water chiller for cooling individual homes or small businesses. The Aqualis 2 can be connected to all types of emitters (underfloor heating and cooling system, fan coil unit type terminal units, water cassettes). Aqualis 2 is designed to be installed externally; no special precautions are needed to protect it from the elements

Description :

  • Air/water chiller in single unit configuration
  • Anti-corrosion casing in recyclable plastic that is UV and weather resistant
  • Scroll compressor
  • Water-cooled brazed-plate heat exchanger
  • Low-speed propeller fan
  • Hydraulic module with accelerator pump and expansion vessel
  • Control terminal with room thermostat (2 wires)
  • Remote µConnect control
  • Auto adaptive functions
  • R-410A refrigerant


AQUACIAT 2 Evolution LD / LDH / LDC

Air-cooled condensation






Range :

20 models available :

  • LD: Without hydraulic system
  • LDC: With hydraulic system, without tank
  • LDH: With complete hydraulic system and tank


Operating range :
Cooling capacity : 20 to 300 kW
Heating capacity : 20 to 285 kW

Use :
Medium-capacity air-cooled chiller for heating and cooling of residential buildings, businesses, industrial facilities and healthcare facilities. May be connected to emitters such as underfloor heating and cooling systems, terminal units (such as fan coil units and water cassettes) or air handling units. Designed as standard for outdoor installation without any special weather protection.

Description :

  • R-410A refrigerant
  • Compact, space-efficient unit
  • Fully encased in a housing constructed of coated metal panels that can be detached for outdoor installation
  • One or two independent refrigerant circuits
  • One to four new-generation, high-efficiency scroll compressors
  • Water-cooled brazed-plate heat exchanger
  • One to four propeller fans
  • User-friendly CONNECT microprocessor-based controller with many self-regulating functions
  • Communication with BMS via an RS-485 interface (Modbus/Jbus) as standard


AQUACIAT POWER HEE & STD LD / LDH / LDC
Air-cooled condensation

Range:

  • AQUACIAT LD-LDC-LDH series
  • High energy efficiency (HEE) A class version
  • Standard energy version (STD) class B
  • LD: water chiller without hydraulic system
  • LDC: water chiller with hydraulic circulation pump
  • LDH: water chiller with hydraulic circulation pump and buffer tank
  • 7 models (1200V to 2400V)
  • 3 sound levels available for both energy versions
  • High Efficiency (HEE) - Low Noise (HEELN) - Xtra Low Noise (HEEXLN) for the HEE version
  • Standard (STD) - Low Noise (STDLN) - Xtra Low Noise (STDXLN) for the standard version


Operating range :
Cooling capacity : 330 to 650 kW

Use :
The new generation of
AQUACIAT air-cooled high efficiency water chillers provides an optimal solution for all cooling applications in offices, healthcare facilities, industries, administration and commercial premises and apartment buildings.
These units are designed to be installed outdoors and require any weather protection.
This new range is optimised to run with the ozone-friendly HFC refrigerant
R410A and thereby meet the most demanding environmental protection and high seasonal energy efficiency (ESEER) requirements.

Description :

  • R-410A refrigerant
  • EUROVENT "CLASS A" or "CLASS B" energy class depending on the energy version.
  • Compact design and small footprint for convenient outdoor installation
  • RAL 7024/7035 metal housing
  • Two independent refrigerant circuits
  • new-generation, high-efficiency scroll compressors
  • High efficiency brazed-plate heat exchangers
  • Electrical cabinet complete with remote-control transformer, safety switch, wire numbers and identifications of the locations of main electrical components
  • Controlled by CIAT's multilingual CONNECT 2 PLC with many anticipatory functions and master/slave control of two machines
  • RS485 output for communication with a BMS (MODBUS/JBUS as standard/LON and Ethernetoptional)


POWERCIAT LX / LXC / LXH
Air Cooled Condensation

Range :

LX: water chiller without hydraulic system LXH: water chiller with hydraulic circulation pumpLXH: water chiller with hydraulic circulation pump and buffer tank
19 models (1800X to 6600X HPS)
Three acoustic versions available: Standard - Low Noise - Xtra Low Noise

Operating range :
Cooling capacity : 370 to 1500 kW

Use :
The new generation of
POWERCIAT air-cooled water chillers provides an optimal solution to all cooling applications in offices, healthcare facilities, commercial premises, industrial facilities and apartment buildings
These units are designed to be installed outdoors and do not require any weather protection.
This new range is optimised to run with the ozone-friendly HFC refrigerant
R134A. They thereby meet the most demanding specifications in terms of environmental protection and high seasonal energy efficiency (ESEER) requirements.

Description :

  • R-134A refrigerant
  • Compact design and small footprint for convenient outdoor installation
  • RAL 7024/7035 metal housing
  • 2 or 3 independent refrigerant circuits
  • 2 or 3 double screw compressors complete with oil seperator and Star Triangle start up.
  • Shell-and-tube dry-expansion evaporator equipped with a water flow switch
  • Electrical cabinet complete with remote-control transformer, safety switch, wire numbers and identifications of the locations of main electrical components
  • Controlled by CIAT's multilingual XtraCONNECT 2 PLC with many anticipatory functions and master/slave control of two machines
  • RS485 output for communication with a BMS (MODBUS/JBUS as standard/LON and Ethernet optional)



CIATCOOLER RTB
Air-cooled condensation

Range :
7 models available in two versions

  • RTB : cooling only
  • ITB : reversible cooling and heating


Operating range :
Cooling capacity : 16 to 20 kW

Use :
Air-cooled chiller with centrifugal fan for cooling of commercial, industrial or healthcare facilities. May be connected to emitters such as terminal units (e.g. fan coil units and water cassettes) or air handling units. Designed as standard for installation in mechanical rooms.
May be protected for outdoor installation.

Description :

  • R-407C refrigerant
  • Compact unit takes up little ground space
  • Fully encased in a housing constructed of detachable coated metal panels
  • One refrigeration circuit
  • One or two compressors
  • Water-cooled brazed-plate heat exchanger
  • One centrifugal fan (available pressure 0 to 300 Pa) with two air flow directions available
  • User-friendly microprocessor-based controller


CIATCOOLER LJA / LJAH
Air Cooled condensation

Range :
10 models available :
- LJA : Cooling-only version without hydraulic system
- LJAH : Cooling-only version with complete hydraulic system and tank

Operating range :
Cooling capacity : 23 to 140 kW

Use :
Air-cooled chiller with centrifugal fan for cooling of commercial, industrial or healthcare facilities. May be connected to emitters such as terminal units (e.g. fan coil units and water cassettes) or air handling units. Designed as standard for installation in mechanical rooms. May be protected for outdoor installation.

Description :

  • R-407C refrigerant
  • Compact unit takes up little ground space
  • Fully encased in a housing constructed of detachable coated metal panels
  • One or two refrigerant circuits
  • One to four new-generation, high-efficiency scroll compressors
  • Water-cooled brazed-plate heat exchanger
  • One centrifugal fan (available pressure: 0 to 300 Pa) with three air flow directions available
  • Horizontal or vertical hydraulic connections
  • User-friendly CONNECT microprocessor-based controller with many self-regulating functions
  • Communication with BMS via an RS-485 interface (Modbus/Jbus) as standard


AQUACIAT FREE COOLING
Air-cooled condensation


Range :
9 models available

Operating range :
Cooling capacity from 190 to 500 kW

Use :
The FREE COOLING system integrated into the AQUACIAT2 and AQUACIATPOWER ranges allows significant energy savings to be made by tapping into the kilo calories contained in the outdoor air as soon as the climatic conditions allow rather than using a refrigerating circuit.
The energy efficiency of the system can thus reach an EER of 60.

Description :

  • Air/water exchange coil placed in front of the water chiller
  • Simultaneous operation with the water chiller
  • Piloting of both the free cooling module and the water chiller via AeroCONNECT optimising the operation of the overall installation and the recovery of calories